Product Positioning

Three-phase energy monitoring terminal for voltage, current, power and energy acquisition with RS485 and optional LTE(4G) or WiFi communication.

Capability 01220VAC / 380VAC power supply
Capability 02110-400VAC voltage measurement range
Capability 030-80A direct input or 0-5A CT input
Capability 04RS485, LTE(4G) and WiFi communication options

Typical Applications

The page is written for engineering companies, system integrators, device manufacturers and B2B project procurement teams.

Distribution cabinetsBuilding energy monitoringFactory equipment circuitsFeed plant energy monitoringOperation trend analysis

Selection Notes for B2B Projects

Measurement ObjectDefine whether the project monitors a single cabinet, multiple outgoing circuits, equipment current, building energy or feed plant energy.
Communication MethodSelect RS485, LTE(4G), WiFi or platform access based on cabinet layout, network conditions and data reporting needs.
Management ValueUse voltage, current, power, energy and trend data for reports, alarms, load comparison and operation quality analysis.

Integration and Deployment

Metering BoundaryDefine the cabinet, feeder, tenant, equipment group or circuit represented by each measurement point.
Electrical SignalsCoordinate voltage and current inputs, phase assignment and circuit naming with the distribution design.
Data TransportUse RS485 or the available network option to deliver readings to a local host or remote platform.
Operational UseTurn voltage, current, power and energy data into trends, comparisons, reports and alarm workflows.

Selection and system combinations

Select metering by three-phase wiring and direct or current-transformer input. Branch accounting and power-quality diagnosis are different data objectives with multi-circuit acquisition and power terminals.

Technical specifications and model data

Product nameAC energy monitoring terminal
Supply220VAC / 380VAC
Voltage range110–400VAC
Current range0–80A direct input; 0–5A CT input
Voltage accuracy±1V
Current accuracy±0.1A
Power accuracy±1W
Device consumption≤3W
Storage conditions-40 to 80°C
Output / communicationRS485 / LTE(4G) / WiFi
Dimensions12.5×10×7.5cm

Product integration and applications

01

Select direct or CT input from the distribution design

The terminal measures three-phase voltage, current, power and energy with direct-input or CT-input configurations. Their wiring, ratios and applicable current conditions differ. Select by the distribution arrangement, load and installation space, then align phases, current direction and settings so that measurements belong to the correct circuit.

AC energy terminal direct-input and CT-input wiring diagrams
AC energy terminal direct-input and CT-input wiring diagrams
02

Combine local display and remote management

The display serves cabinet-side inspection, RS485 integrates with existing control systems, and optional 4G or WiFi supports the corresponding network architecture. Group platform data by building, floor, cabinet and equipment. Field staff verify wiring and readouts; managers compare locations and periods using the same point definitions.

03

Connect electrical data to practical operating questions

Review after-closing lighting demand, factory shifts, farm ventilation and heating, or property common-area energy. Correlate unusual trends with control logs, equipment states and field conditions to identify inspection priorities. Consistent periods and grouping make before/after policy comparisons more meaningful.

Selection questions

Are direct-input and CT-input units wired the same way?

No. Their current paths, CT connections and ratio settings differ. Use the wiring definition for the selected configuration.

Can it help evaluate lighting policies?

Yes. Correlate current, power and energy with switching, schedules and scenes using matching periods and circuits.

Selection FAQ

What power data can be collected?The devices can collect voltage, current, power, energy and related operating data according to the product type and wiring method.
Where are energy monitoring products used?They are used in distribution cabinets, buildings, factories, equipment rooms, feed plants and energy operation projects.
Can energy data be sent to a platform?RS485, LTE(4G), WiFi or gateway access can be selected according to the product and project architecture.

Contact Zhenming Electronics

Call us or leave your contact details for product selection and project enquiries.

Call us+86 16605298829Taobao Store ↗
Quote list 0