Zhenming Electronics
Smart lighting and relay control module

50A High-Power Magnetic Latching Relay Controller

8-channel network relay controller with 50A magnetic latching relays, eight dry-contact inputs, Ethernet, two RS485 ports, CAN, 16 schedules and multiple output modes for smart lighting and high-power circuit control.

ZMRN0808-QC8 50A High-Power Magnetic Latching Relay Controller product image
SELECT & PURCHASE

Choose a configuration

Tax-inclusive reference prices in CNY. Negotiable; the quotation reflects the selected configuration, quantity and delivery requirements. All products carry a 3-year warranty.

Purchase guide & prices →
Reference unit priceRequest a quotationDiscuss the model and project quantity

For a complete system, include the power supply, sensors, communication access and platform deployment in your enquiry.

Product Positioning

8-channel network relay controller with 50A magnetic latching relays, eight dry-contact inputs, Ethernet, two RS485 ports, CAN, 16 schedules and multiple output modes for smart lighting and high-power circuit control.

Capability 018 independent 220V dry-contact relay outputs
Capability 028 dry-contact inputs for buttons, limit switches and field contacts
Capability 03Ethernet, two RS485 ports and one CAN interface
Capability 0416 schedules plus switch, momentary, toggle, interlock, motor/lift and hidden-channel modes

Typical Applications

The page is written for engineering companies, system integrators, device manufacturers and B2B project procurement teams.

Agricultural local automationGreenhouse environment controlLivestock ventilation linkageCinema and exhibition lightingControl cabinets and remote switching

Selection Notes for B2B Projects

Circuit and Load TypePlan the eight outputs by lighting or equipment circuit, then verify resistive, inductive or capacitive inrush characteristics instead of selecting only by the 50A relay rating.
Local Inputs and ModesUse the eight dry-contact inputs for buttons, limit switches or field contacts, and select switch, momentary, toggle, interlock, motor/lift or hidden-channel operation as required.
Communication and SchedulesUse Ethernet, two RS485 ports or CAN for project integration, with 16 schedules, platform access and status feedback for operations.

Integration and Deployment

Circuit ObjectsMap each output to a named lighting, pump, fan, valve, cabinet or equipment circuit and retain a clear control boundary.
Local OperationUse dry-contact inputs, wall panels, schedules or supported local rules for field operation when the selected model provides them.
Network OperationsUse the communication interfaces of the selected model for status, remote control, action records and multi-site management.
Electrical CoordinationCoordinate relay loads, contactors, protection, cabinet wiring and manual override with the electrical design.

Local Sensor Automation for Agriculture

Supported controller hardware and firmware can read Zhenming RS485 environmental sensors, evaluate downloaded upper and lower thresholds on site, and drive the mapped output without a cloud round trip. The platform remains available for rule configuration, state, remote operation and linkage logs.

On-device ruleRS485 sensorOffline executionUpper/lower thresholdsFans and pumpsValvesField alarmsRemote operations

Selection and system combinations

QC8 provides multi-circuit high-power latching switching. Select by actual loads and circuits; brightness adjustment and energy measurements still require the corresponding dimming and metering devices.

Technical specifications and model data

ModelZMRN0808-QC8
Product type8-channel network relay controller
Supply12V; standard 12V/1A supply
Output ports8 independent dry-contact outputs for 220V circuits
Input ports8 input ports
Communication interfaceEthernet, 2 RS485 ports and 1 CAN port
Network protocolsTCP, UDP, MQTT
TCP port1234
UDP port9128
Integration functionsModbus RTU to Modbus TCP; RS485 to MQTT; DMX512; RS485 Modbus RTU control
Relay specification50A 277V AC magnetic latching relay
Maximum output voltage/current and switching lifeAC220V/50A; more than 100,000 operations
Power consumption0.8W standby; 3W maximum
Operating temperature-40 to 85°C
Storage temperature-40 to 85°C
Storage humidity5%–95% RH
Mounting35mm DIN rail
Enclosure dimensions180×100×65mm (L×W×H)

Product integration and applications

01

Eight power circuits with eight field inputs

ZMRN0808-QC8 combines eight 50A magnetic latching relay outputs and eight dry-contact inputs in one DIN-rail device. Map cinema light groups, exhibition zones, floor lighting or equipment circuits to clear channel names. Local buttons and contacts provide inputs; relays execute the outputs. A consistent IO register supports both field operation and platform grouping.

QC8 eight-channel controller enclosure, terminals, Ethernet port and dimensions
QC8 eight-channel controller enclosure, terminals, Ethernet port and dimensions
02

Ethernet, dual RS485 and CAN roles

Ethernet supplies the wired network path. The two RS485 ports serve the configured upstream or field-device roles, and CAN supports the corresponding project integration. Panels, sensors and meters each have distinct jobs. Match master/slave roles, protocols and addresses to the chosen devices; sharing a physical interface alone does not establish interoperability.

QC8 CAN terminals and the configurable and slave RS485 interface locations
QC8 CAN terminals and the configurable and slave RS485 interface locations
03

Choose a switching mode for the task

Use maintained switching for steady on/off loads, momentary output for start or reset pulses, and toggle for alternating button actions. Interlock and motor/lift modes serve suitable paired-channel tasks; hidden channels reduce unnecessary operation. Sixteen schedules support work, duty, cleaning and closing policies. Keep control policies aligned with field feedback and equipment protection.

04

Build a complete lighting control system

QC8 can switch zone circuits and equipment supplies, while a ZMSR0004-1G module provides 0-10V setpoints to compatible drivers. Energy devices add current, power and energy feedback, and ZMLCD panels provide local scenes. The platform groups these functions around operating zones and workflows, from a single cabinet to multiple managed areas.

Selection questions

Does magnetic latching mean the whole controller works without power?

No. Latching describes the relay state mechanism. Communication, processing and scheduled execution still require the controller supply.

Does QC8 directly dim lamps?

QC8 switches circuits. Add a 0-10V module and compatible driver for brightness control, coordinated through a panel or platform.

Can every lamp load be sized only from the 50A rating?

No. Inrush, driver type, cabling, protection and temperature rise also determine the circuit design.

Selection FAQ

What control projects are suitable for QC8?QC8 is designed for eight high-power lighting or equipment circuits in cinemas, exhibition halls, parks, campuses, hospitals, buildings and control cabinets.
Which communication interfaces are available?The controller provides Ethernet, two RS485 ports and one CAN interface, with TCP, UDP, MQTT and project integration capabilities.
Which output modes are supported?Switch, momentary, toggle, interlock, forward/reverse or lift, and hidden-channel modes are supported. Momentary time can be set from 0 to 6000 seconds.
How should a 50A relay be selected for different loads?Resistive, inductive and capacitive loads have different inrush characteristics. Circuit selection should follow the actual lamp or equipment data, contactor configuration and cabinet design.

Contact Zhenming Electronics

Call us or leave your contact details for product selection and project enquiries.

Call us+86 16605298829Taobao Store ↗
Quote list 0