Zhenming Electronics
4G remote control module

1-Channel 4G Remote Control Module

1-channel 4G remote control module for mobile, web and PC remote switching, status feedback, 16 schedules, cyclic operation, device sharing and switch, momentary or toggle output modes.

1-Channel 4G Remote Control Module ZMRG0101-L1/L1D product image
SELECT & PURCHASE

Choose a configuration

Tax-inclusive reference prices in CNY. Negotiable; the quotation reflects the selected configuration, quantity and delivery requirements. All products carry a 3-year warranty.

Purchase guide & prices →
Reference unit priceRequest a quotationDiscuss the model and project quantity

For a complete system, include the power supply, sensors, communication access and platform deployment in your enquiry.

Product Positioning

1-channel 4G remote control module for mobile, web and PC remote switching, status feedback, 16 schedules, cyclic operation, device sharing and switch, momentary or toggle output modes.

Capability 01ZMRG0101-L1: 220V power supply and 40A relay output
Capability 02ZMRG0101-L1D: 9-24V power supply and 10A relay output
Capability 03Mobile, web and PC management with device sharing and status feedback
Capability 0416 schedules, cyclic operation and switch, momentary or toggle output modes

Typical Applications

The page is written for engineering companies, system integrators, device manufacturers and B2B project procurement teams.

Smart lighting and grouped circuit controlIndustrial equipment status acquisition and remote switchingLivestock monitoring, weighing and equipment linkageEnergy monitoring, operation records and remote maintenancePrivate deployment and customer system integration

Selection Notes for B2B Projects

Control ObjectPlan the product by lighting circuit, pump, fan, cabinet output or equipment switching object instead of only by channel count.
Protocol and PlatformCheck whether the project needs RS485, Ethernet, LTE(4G), MQTT, Modbus, grouped control, schedules, logs or private platform deployment.
Circuit PlanningSeparate high-power, inductive and frequently switched loads into clear circuits and match controller selection with the cabinet design.

Integration and Deployment

Circuit ObjectsMap each output to a named lighting, pump, fan, valve, cabinet or equipment circuit and retain a clear control boundary.
Local OperationUse dry-contact inputs, wall panels, schedules or supported local rules for field operation when the selected model provides them.
Network OperationsUse the communication interfaces of the selected model for status, remote control, action records and multi-site management.
Electrical CoordinationCoordinate relay loads, contactors, protection, cabinet wiring and manual override with the electrical design.

Selection and system combinations

Select L1 or L1D single-circuit 4G control by supply and load. Compare the energy-aware ER1 for power data and multi-channel 4G ranges for additional circuits.

Technical specifications and model data

Product family1-channel 4G remote controller
ModelZMRG0101-L1 / ZMRG0101-L1D
L1 versions220V supply; 10A or 40A relay options
ZMRG0101-L1D9–24V supply; 10A relay output
Control channels1 relay output
Remote managementMobile and computer remote control, schedules and status viewing
Schedules16 schedules with weekday settings
Cyclic operationCyclic on/off operation, combinable with schedules
Output modesSwitch, momentary and toggle
Management accessMobile, web platform, PC management client and device sharing
Typical applicationsSmart lighting, pumps, irrigation, fans and small equipment remote switching
Plug-in optionsL1D supports NTC temperature and AB/RS485 plug-ins
Operating temperature-25 to 80°C
Storage temperature-40 to 85°C
Storage humidity5%–95% RH
L1D enclosure dimensions100×55×35mm

Product integration and applications

01

Select supply and relay specification first

The L1 family provides single-circuit 4G remote switching. The 220V supply versions offer 10A or 40A relay options; L1D uses a 9–24V supply and a 10A relay. Select the supply and relay version for the lighting cabinet, pump, fan or low-voltage equipment. Contactors can handle larger loads or high starting currents.

02

Use schedules, cycles and pulses for distinct tasks

Sixteen weekly schedules suit fixed operating periods, while cyclic operation serves intermittent irrigation, aeration or ventilation. Momentary mode supplies a short trigger; toggle reverses the output state. Define a clear routine for the single load and use mobile, web or PC management for authorized adjustments, sharing and inspection.

03

Extend remote switching with field information

Name each device by site and purpose, then group it on the platform. L1D supports the corresponding NTC or AB/RS485 plug-in option. Add separate acquisition when current, energy or independent running feedback is required. Connectivity, relay state and actual equipment operation are distinct data points that can be combined in the project view.

Selection questions

Do L1 and L1D use the same supply?

Select supplies separately: L1 uses 220V with 10A or 40A relay options; L1D uses 9–24V with a 10A relay.

Which function suits intermittent ventilation?

Use cyclic operation for repeated on/off periods and combine it with the 16 weekly schedules for the desired operating window.

Selection FAQ

What lighting or control projects are suitable?These relay controllers are used for smart lighting, control cabinets, equipment switching, parks, streets, campuses, hospitals, cinemas and exhibition halls.
How should relay channels be selected?Channel count should follow the number of lighting circuits, equipment groups, cabinet layout and expansion margin.
Can the controller support remote operation?Depending on the model, RS485, Ethernet, 4G, MQTT, TCP, UDP or platform access can support remote control and status viewing.

Contact Zhenming Electronics

Call us or leave your contact details for product selection and project enquiries.

Call us+86 16605298829Taobao Store ↗
Quote list 0